INDUSTRIAL HYGIENE SAMPLING OF GASES AND VAPORS UNIVERSITY OF HOUSTON - CLEAR LAKE SPRING 2015 PURPOSE Introduce techniques to evaluate EXPOSURES to gases and vapors arising in or from the workplace. Additionally: - be aware of technology for assessment of environments; - indoor and ambient air; and, - capabilities and limitations of

various referenced methods. SAMPLING GASES AND VAPORS When developing a sampling strategy, review available sampling and analytical methods for contaminants of interest. Select most suitable! e.g. OSHA, NIOSH i.e.

published and validated methods. EPA methods used for lower level indoor SAMPLING METHOD Select a method that meets sampling and analytical ACCURACY and PRECISION requirements of the

referenced standard in unique field conditions. Usually stipulate measurement at the PEL within +/- 25% of the true value at a 95% confidence level. EPA related to ambient air. ANALYTICAL LABORATORY Select and consult with qualified analytical laboratory, e.g. AIHA for participation in appropriate Laboratory Accreditation Programs. Labs assist with method choice that meet

sensitivity and specificity criteria for environment under evaluation. Choose sampling media and strategy compatible with method and review special handling. Two key factors: knowledge of occupational environment AND overall perspective of the limitation of the

chemistry of sampling/analysis parameters. SENSITIVITY Exercise caution when using traditional workplace sampling method for measuring contaminants in indoor or ambient air because expected concentrations may be below the working range. To obtain sensitivity, NIOSH recommends exceeding recommended air volume while observing the suggested maximum flow rate. The conservative value protects against break-through (e.g. primary vs. back-up

sections of sampler) under worst-case conditions of high %RH and/or concentrations. GAS/VAPOR For IH purposes, a substance is a GAS if this is normal physical state at room temperature (25 degrees C) and one-atmosphere pressure. Examples: CO, Cl, Oxygen, and Nitrogen. If substance is normally a liquid at normal temperature and pressure, then the gaseous component in equilibrium with liquid state is a

VAPOR. SAMPLING PLAN Designing a sampling plan involves consideration of the following: - location of samples, - number of workers, and - duration of sampling. Also other factors: - noise, - equipment,

- size, - flow rate, and - security of equipment/sample integrity. SAMPLE TYPES Two basic types of samples used to assess employee exposure: - Integrated - Grab. INTEGRATED SAMPLING For gases and vapors, passage of a known volume of air through an ABsorbing or ADsorbing medium to remove the desired air contaminants during defined time period.

Absorb penetration into material; physically dissolve or chemically react with sample medium. Adsorb traps airborne chemicals onto surface. Contaminants of interest are collected and concentrated over time to obtain the average exposure levels during the entire sampling period. GRAB SAMPLING Direct collection of an air-contaminant mixture into a device (i.e. sampling bag, syringe, or evacuated flask) over a short interval of a few seconds or

minutes. Represents the atmospheric concentrations at the sampling site at a given point in time. WHOLE AIR SAMPLING Collection of air into a sealable container (e.g. stainless steel canister or sampling bag) for subsequent analysis. Example: Figure 11.10 [insert

follows] Obtained over a short period of time as grab samples OR integrated over a longer period of time to obtain Time-Weighted INTEGRATED SAMPLING Cover the entire period of exposure required because airborne

contaminant concentrations during a typical work shift vary with time and activity! Grab samples do not reflect average exposures. Most integrated sampling is done to determine the 8-hour TWA and/or STELs for comparison with OSHA PELs, ACGIH TLVs and NIOSH Personal Pocket Sampling Pump INTEGRATED SAMPLING CONSIDERATIONS

Appropriate sample duration and flow rate chosen relative to the purpose of sampling, sensitivity of analytical method, and expected concentration of contaminant. Accurate measurement of flow rate and time which depends on precise determination of the mass of contaminant collected and volume of air sampled.

ACTIVE SAMPLING Means of collecting an airborne substance with a mechanical device such as air sampling pump to draw the air/contaminant mixture into or through the sampling device. Examples: sorbent tube, treated filter, or impinger containing a liquid media. A key element is calibration that reliably measures the pump flow rate, thus allowing for

an accurate ACTIVE SAMPLING Uses mechanical device to collect airborne substance such as air sampling pump to draw the air/contaminant mixture into or

through the sampling device. AIR SAMPLING PUMPS Integrated methods require relatively constant source of suction calibrated to recommended flow rate (within +/- 5% with collection media in-line). AIR SAMPLING WITH PUMPS Personal sampling (i.e. breathing zone)

OR area sampling for potential source(s). Features constant flow capabilities/back pressure; intrinsically safe; etc. Maintain desired flow rate over the

entire sampling period with in-line sample collection device. CALIBRATION Pump flow must be calibrated with the entire sampling train assembled as used. Good IH practice requires both preand post-pump calibration on the same day under pressure and

temperature conditions similar to those at site. Not addressed with built-in rotameters (not precision devices and do not provide a quantitative measure CALIBRATION STANDARDS Two Terms: Primary direct and measurable linear dimensions

(length and diameter of cylinder). Examples: meters spirometers and bubble

Secondary flowmeters that trace calibration to primary standards and maintain accuracy with reasonable care and handling in operation. Examples: precision rotameters, wet test meters, and dry gas meters SAMPLE COLLECTION MEDIA Consult published

air sampling methods to determine the appropriate collection media for a specific chemical contaminant. Review methods to determine applicability relative to

field conditions. Such as: VP, BP, reactivity; interferences, also humidity/temperature effects, proper measuring range; physical state of ACTIVE SAMPLING ADVANTAGES - Select method used by compliance personnel during OSHA inspection.

- Offers calibrated, measured airflow for assurance in accuracy of sample volume. Sorbent tube samples have a secondary layer for back-up indicating break-through. - Multiple phases can be assessed by a series of samplers. ACTIVE SAMPLING DISADVANTAGES

- Cumbersome equipment and may interfere with job tasks during shift for personnel. - Pump calibration is time consuming and requires technical training. - Pump may become somewhat less reliable at maintaining constant flow over the entire sampling period, and more frequent calibration may be necessary. PASSIVE SAMPLERS Passive sampling is the collection of airborne gases and vapors at a rate

controlled by a physical process such as diffusion through a static air layer or permeation through a membrane without the active movement of air through sampler. Operate on principle of diffusion. Organic Vapor Monitoring Badges PASSIVE SAMPLERS Performance characteristics evaluated in the NIOSH Validation Protocol include: - Analytical recovery - Sampling rate and capacity

- Reverse diffusion - Storage stability - Analyte concentration - Exposure time - Face velocity PASSIVE SAMPLERS Performance characteristics evaluated in the NIOSH Validation Protocol include: - Relative humidity - Interferences - Monitor orientation - Temperature - Accuracy and precision - Shelf life

- Behavior in field DIFFUSIVE SAMPLERS Rely on movement of contaminant molecules across a concentration gradient, which for steady-state conditions can be defined by: Ficks first law of diffusion. Consist of diffusion gap between

external air and a sorbing medium to collect chemicals of interest, but also to maintain the concentration as close to zero as possible at the end of the diffusion path. DIFFUSIVE SAMPLERS Each gas/vapor sampled has a specified diffusion coefficient (D). Uptake rates can vary under various field conditions. Validation! See Equations and Units on Page 274 (Third Edition). OSHA ISSUES Report

(1998) attempted to determine sampling rate variation of specific passive sampler designs. Concept of passive sampling equated to active sampling with pump error of +/- 5%. Significant - use of sampling rate variation for passive sampler along with the analytical error component allowed calculation of the overall Sampling and Analytical Error (SAE). SAE must be used by OSHA inspectors along with sample results to determine if PEL exceeded.

Therefore, passive sampling methods can be used by OSHA. PASSIVE SAMPLERS Various types are commercially available. Some samplers designed to collect broad range of compounds, whereas others due to collection

media preferentially obtain a single chemical or family of chemicals. Examples: activated charcoal sorbent organic vapors and GC analysis; chemical treated sorbents or filter paper for HPLC analysis. Direct-reading passive samplers based on colorimetric techniques; may not be PASSIVE SAMPLING ADVANTAGES - Easy to use, samples can be collected by personnel with less technical training.

- Less expensive. - Less obtrusive for wearer. - For most applications, the mass of contaminant collected by passive samplers is not significantly affected by temperature or pressure. PASSIVE SAMPLING DISADVANTAGES May not be OSHA/NIOSH methods referenced in order to

insure reliability of data. Sampling rate, if theoretically calculated, may not prove valid under field conditions. - Reverse diffusion may be a factor. - Environmental parameters may influence the collection efficiency of passive samplers. Examples: stagnant air; high face velocities.

- Low uptake rates may not provide sensitivity required for low-level GRAB SAMPLING Collected sample measures gas and vapor concentrations AT A POINT IN TIME and used to evaluate PEAK exposures for comparison to Ceiling limits. Identify unknown contaminants,

evaluate contaminant sources, or measure contaminant levels from intermittent processes/other sources. Collected using syringes, canisters, or bags, etc. Instantaneous (as well as integrated) Colorimetric Tubes and Sampling Pump

Colorimetric Gas Detection Tubes GRAB SAMPLING ADVANTAGES - After collection, frequently analyzed immediately by GC or direct-reading instruments. - Therefore, quick decisions made in field/site about source of leaks; Confined Space Entry (CSE); PPE, etc.

GRAB SAMPLING DISADVANTAGES - For most applications, contaminants are collected but not integrated over time. Only some devices will allow use of a metering device to collect sample(s) at or near constant flow over period of time for TWA. - For low contaminant concentrations, analytical instrument may not be

sensitive for detection. - Multiple grab samples to assess fullshift exposures is time-consuming OPERATIONAL LIMITS OF SAMPLING AND ANALYSIS Inherent limitations of method: Sampler capacity Limit of Detection (LOD) Limit of Quantification (LOQ) Upper measurement limits define useful range of referenced method. These factors determine the minimum, maximum, or optimum volume of air to be

sampled and also confidence that can be placed in the results. Discuss with lab before sampling! SAMPLER CAPACITY Predetermined conservative estimate of total mass of contaminant that can be collected on medium without loss or overloading. NIOSH definition of 2/3 of experimental break-through capacity of the solid sorbent [i.e. 67% of

mass of contaminant on sorbent at the breakthrough volume]. Break-through volume is: volume of an atmosphere containing two times the PEL for the contaminant that can be sampled at the recommended flow rate LIMIT OF DETECTION (LOD) Lowest concentration level determined to

be statistically different from a blank sample. Recommended value of the LOD is the amount of analyte that will give rise to a signal that is three times the standard deviation of the signal derived from the media blank. LIMIT OF QUANTIFICATION (LOQ) Concentration level above which quantitative results may be obtained with a certain confidence. Recommended value of the LOQ is the

amount of analyte that will give rise to a signal that is ten times the standard deviation of the signal from a series of media blanks. Corresponds to a relative uncertainty in the measurement of +/- 30% at 99% DETECTION LIMIT (DL) Described both in terms of: - DL of the analytical procedure, and - DL of the overall procedure. OSHA reports, in

general, that detection limits (DL) are defined as: amount of analyte that gives a response that is significantly different (three SD) from the background response. UPPER MEASUREMENT LIMIT Useful limit of the analytical

instrument (mg of analyte per sample). Sample above Upper Measurement Limit, then re-dilute and re-analyze. Review and discuss with analytical lab. TARGET CONCENTRATION Preliminary estimate of airborne contaminant concentration relative to the purpose of testing. Parameter can be used to determine the minimum and maximum air volumes. Can be estimated by: using previous

sampling data, use of direct-reading instruments, or by relying on the professional judgment of the IH. CALCULATIONS Sample volumes minimum and maximum. Working range is range of contaminant concentration that may be quantitated at a specified air volume.

Lower boundary of working range is defined by a sample that has a mass of contaminant equal to the LOQ. Upper boundary is defined by sampler capacity. SOLID SORBENT MEDIA Adsorb onto surface; Effectiveness determined by: Trap and retain nearly all contaminants from air Amenable to desorption from sorbent

Sufficient capacity to retain contaminant quantity for analysis without large media pressure drop Not cause chemical change of contaminant

except by analytical method as needed Absorb contaminant of interest in COLLECTION EFFICIENCY OF SOLID SORBENTS Various Factors: Temperature Humidity Sampling Rate Other Contaminants Sample Break-through - 25% - Migration

DESORPTION - Solvent extraction extract contaminants of interest from adsorbent materials. Examples: carbon disulfide; mixtures. - Thermal desorption

drive contaminant off sorbent by high temperature; entire mass of contaminant introduced directly into analytical instrument without DESORPTION EFFICIENCY Measure of how much analyte can be recovered from the sorbent tube; determined typically at 0.1, 0.5, 1, and 2 times target concentration

based on the recommended air volume and expressed as a percentage of analyte spike on media. To be determined for each lot number of solid sorbent used for sampling and also done in the concentration range TYPES OF SORBENT MATERIALS

Inorganic Sorbents silica gel (polar; %RH); less reactive than charcoal Elemental Carbon charcoal types; organics; high adsorptive capacity; stable compounds; high humidity parameters Carbonized or Graphitized Sorbents low to moderate surface

area; intermediate to high volatility; stable compounds for thermal desorption Sorbent Tubes Sorbent Tubes TYPES OF SORBENT MATERIALS Organic Polymers - selectivity to particular applications, and stability at high temps enables thermal

desorption (i.e. Tenax broad range of organics can be collected). Other Sorbent Materials sorbents with PUF; sorbent combinations; sorbent/filter combinations OVS, etc. Sorbent Tubes OTHER MEDIA

Chemically treated derivatize/desorb Liquid absorbers filters Gas washing bottles e.g. impingers Fritted glass bubblers

Filter Cassettes Filter Cassettes OTHER MEDIA Sampling containers/canisters bags/evacuated

Situations: direct-reading instruments; leaks/emergencies; peaks; highly volatile compounds Precautions storage time; diffusion. reaction; CALCULATIONS

Total Mass of Contaminant Airborne Concentration by sample volume (mass over volume) Air Volume (flow rate x sample time) Unit Conversions mg/M3 to/from ppm Temperature/Pressure Corrections Time-Weighted Averages (TWA) Potential Work Shift Adjustments See Formulas and other Handouts/PPTs.

CALCULATIONS Unit Conversions mg/M3 to/from ppm Temperature/Pressure Corrections Time-Weighted Averages (TWA) Potential Work Shift Adjustments Formulas on Page 286-287 (Third Edition).

REMEMBER CALCULATIONS Range of temperature and pressure changes tolerated before corrections are applied to the volume of air sampled. All OELs and environmental exposure standards and limits are expressed at 25 degrees C and 1 atmosphere (760 mm Hg), defined as normal

temperature and pressure (NTP). Therefore, corrections needed for meaningful comparisons to published

Recently Viewed Presentations

  • UCL HUMAN RESOURCES HR User Group  08 March

    UCL HUMAN RESOURCES HR User Group 08 March

    Provides leadership to ensure that UCL is ready and able to accept and work with Oracle and the new business processes to be implemented. Influences positive change and serve as advocates for . MyHR. ... PowerPoint Presentation Last modified by:
  • The Giver - pdsd.org

    The Giver - pdsd.org

    The Giver. Some examples from American history include the Oneida Community, the Shakers, the Harmonists, and Brook Farm. Some modern American utopian communities include Victory City, Utopian States, and The Principality of New Utopia.Other links to browse:
  • Chapter 4 Reactions in Aqueous Solution 1. 2.

    Chapter 4 Reactions in Aqueous Solution 1. 2.

    If the mass of silver bromide precipitate that forms was 0.0964 g, what is the percent of Br- ion by mass in the original compound? Acid-Base Titrations A titration is a procedure for determining the concentration of an unknown acid...
  • NOAA-CREST Algorithm Development Activities Led by  Pat McCormick

    NOAA-CREST Algorithm Development Activities Led by Pat McCormick

    Bloom . Detection in WFS by VIIRS obstructed by lack of 678 nm Chl fluorescence band used with MODIS & MERIS for . HAB. detection- - New CREST approach for VIIRS uses 486, 551 and 671 bands for neural network...
  • Strangeness Report - saske.sk

    Strangeness Report - saske.sk

    experimental overview Federico Antinori (INFN Padova & CERN) Disclaimer This selection is biassed and incomplete: too much material, not enough time I concentrated on flavour results and my personal selection at that in particular: in preparing this talk I have...
  • Manual Handling Training: Programme

    Manual Handling Training: Programme

    Health and Safety at Work etc Act 1974 2. Management of Health and Safety at Work Regulations 1999. 3. Manual Handling Operations Regulations 1992. 4. LOLER regulations 1998 Why is this important? In year 2000 : 50% of U.K. population...
  • Overview of ITIL

    Overview of ITIL

    Tipos de CI: Hardware, Software, Documentação e IT Staff Configuration Management Palavras Chaves: Item de Configuração(CI) - componente que está sobre o controle do CM CM Database (CMDB) - contém todos os detalhes das CIs e as relações entre eles...
  • team5midterm/PPT_Midterm.pptx at master...

    team5midterm/PPT_Midterm.pptx at master...

    Contribute to tushargl016/team5midterm development by creating an account on GitHub.